Getting Started with CapSense
®
Document No. 001-64846 Rev. *I 21
Figure 2-15. Linear Slider
2.5.2.2 Diplexed Sliders
In a diplexed slider, each CapSense controller I/O pin is connected to two different slider segments. This allows a
design to have twice as many slider segments as there are I/O pins. For example, a diplexed 16-segment slider
requires only eight CapSense controller I/O pins.
Figure 2-16. 16-Segment Diplexed Slider
For a diplexed slider to work properly, the slider segments must be connected to the CapSense controller I/O pins in
a pre-determined order. The first half of the segments are connected to the CapSense controller I/O pins sequentially
(0, 1, 2 …7) and operate similar to a linear slider. The second half of the segments are connected to the same
CapSense controller I/O pins in a non-sequential order. This order exploits the fact that activation of one segment
results in partial actuation of neighboring segments. While slider actuation of one half of the slider results in aliasing
on to the other half, the levels will be scattered in the untouched half. Sensing algorithms search for strong adjacent
segment actuation and ignore scattered actuation to determine finger position on the slider accurately.